KeyTec® Luminescent 3D Cell Viability Detection Kit

    Luminescent Assay for Detecting the Number of Viable Cells in 3D cells culture

    • Easy to Use: A homogeneous assay - just follow the 'add-incubate-measure' process • High Sensitivity: Stronger lysis ability, Wider linear range with low background and high signal • The luminescence signal is not only high but also robust, with a half-life of approximately 3-5 h. It is suitable for most assay formats
Size: 10 mL2*50 mL10*50 mL2*250 mL
Price: $ 144
CAT.: A2010201N
Delivery: Available in Stock
KeyTec® Luminescent 3D Cell Viability Detection Kit

    Luminescent Assay for Detecting the Number of Viable Cells in 3D cells culture

    • Easy to Use: A homogeneous assay - just follow the 'add-incubate-measure' process • High Sensitivity: Stronger lysis ability, Wider linear range with low background and high signal • The luminescence signal is not only high but also robust, with a half-life of approximately 3-5 h. It is suitable for most assay formats
Size: 10 mL2*50 mL10*50 mL2*250 mL
CAT.: A2010201N
Delivery: Available in Stock
Price: $ 144
Overview
KeyTec® Luminescent 3D Cell Viability Detection kit (3D LCV) is designed for 3D cell viability detection. It quantifies viable cells by measuring the ATP present, a key indicator of metabolically active cells. The homogeneous assay procedure involves adding a single reagent directly to 3D cells cultured in serum-supplemented medium. The detection principle is based on Luminescent technology. Within the kit, D-Luciferin and luciferase react with ATP released by 3D cells, generating a sensitive and robust luminescent signal. With a luminescent signal half-life of 3-5 hours, this kit ensures high sensitivity and robust performance, making it an ideal choice for high-throughput screening (HTS), 3D cell proliferation and cytotoxicity assays.
Performance
Use KeyTec® Luminescent 3D Cell Viability Detection kit to detect 3D cell viability of Hela cell line. The results showed a linear relationship between the luminescent signal and the number of cells (5 - 200,000 cells/well). Hela cells, cultured in RPMI 1640 medium with 10% FBS, were serially diluted two-fold, starting from 200,000 cells per well in a 96-well plate. Perform the assay according to the procedure outlined in Section 5.“Assay Procedure”. Ten minutes after adding the reagent, measure the luminescent signal using the Envision's Luminescence program. (Example program details include Mirror: Luminescence, Em filter: Luminescence 700, Measurement height: 6.5 mm, and Measurement time: 1 s).
Protocols
Protocol_A2010201N ∕ A2010202N ∕ A2010203N ∕ A2010204N _KeyTec® Luminescent 3D Cell Viability Detection Kit_VKEYBIO-02-2024.pdf
Components
CAT.
Description
Size
A2010201N
KeyTec® Luminescent 3D Cell Viability Detection Kit
10 mL
Each kit contains sufficient reagents to perform 100 tests of 100 μL/well. The kit contains the following components: • 1 × 10 mL KeyTec® Luminescent 3D Cell Viability Detection Reagent
Notices
Certificate of Analysis
Limitations
Storage Conditions
For research use only

-40 ℃

Related Products
Overview
KeyTec® Luminescent 3D Cell Viability Detection kit (3D LCV) is designed for 3D cell viability detection. It quantifies viable cells by measuring the ATP present, a key indicator of metabolically active cells. The homogeneous assay procedure involves adding a single reagent directly to 3D cells cultured in serum-supplemented medium. The detection principle is based on Luminescent technology. Within the kit, D-Luciferin and luciferase react with ATP released by 3D cells, generating a sensitive and robust luminescent signal. With a luminescent signal half-life of 3-5 hours, this kit ensures high sensitivity and robust performance, making it an ideal choice for high-throughput screening (HTS), 3D cell proliferation and cytotoxicity assays.
Performance
Use KeyTec® Luminescent 3D Cell Viability Detection kit to detect 3D cell viability of Hela cell line. The results showed a linear relationship between the luminescent signal and the number of cells (5 - 200,000 cells/well). Hela cells, cultured in RPMI 1640 medium with 10% FBS, were serially diluted two-fold, starting from 200,000 cells per well in a 96-well plate. Perform the assay according to the procedure outlined in Section 5.“Assay Procedure”. Ten minutes after adding the reagent, measure the luminescent signal using the Envision's Luminescence program. (Example program details include Mirror: Luminescence, Em filter: Luminescence 700, Measurement height: 6.5 mm, and Measurement time: 1 s).
Protocols
Protocol_A2010201N ∕ A2010202N ∕ A2010203N ∕ A2010204N _KeyTec® Luminescent 3D Cell Viability Detection Kit_VKEYBIO-02-2024.pdf
Components
CAT.
Description
Size
A2010201N
KeyTec® Luminescent 3D Cell Viability Detection Kit
10 mL
Each kit contains sufficient reagents to perform 100 tests of 100 μL/well. The kit contains the following components: • 1 × 10 mL KeyTec® Luminescent 3D Cell Viability Detection Reagent
Notices
Certificate of Analysis
Limitations
Storage Conditions
For research use only

-40 ℃

Related Products

Shanghai VKEY Biotechnologies Co.,Ltd.

Tel: 021-5835-6939

Email: business@vkeybio.com

Official WeChat Account

沪ICP备2021012748号

Shanghai VKEY Biotechnologies Co.,Ltd.

Tel: 021-5835-6939

Email: business@vkeybio.com

Official WeChat Account

沪ICP备2021012748号
WeChat

Sales Assistant:

Technical-Support:

WeChat Official Account:

Contact Us

Technical Support Email: technical-support@vkeybio.com

BD Email: business@vkeybio.com

Tel:
021-5835-6939

Cooperation